[Materials data sheet]
Daicel PP

Properties Test method Test condition Unit Talc reinforced GF-reinforced Flame retardant Conductive
General purpose Easy flow Impact resistant For Extrusion General purpose GF/Maica V-2 V-0 Rigid Halogen-Free General purpose V-1
10% 15% 20% 30% 40% 15% 20% 30% 40% 20% 30% 10% 20% 30% 35% - - 25% - - -
PT2N1 PT3N1 PT4N1 PT6N1 PT8N1 PT3F1 PT4F1 PT6F1 PT8F1 PTS4N1 PT6E1 PG2N1 PG4N1 PG6N1 PGM7T1 PNAS3 PNAK2 FP994 PNAN5 PB2N1 PB6N3
Melt mass-flow rate
ISO 1133
230℃/2.16kg
g/10min
12 12 12 12 8 25 25 20 13 10 1.1 9 8 7 4 21 11 3 18 8 33
Mold shrinkage
ASTM D955
  %
1.2-1.5 1.1-1.4 1.0-1.3 0.9-1.2 0.8-1.1 1.1-1.4 1.0-1.3 0.9-1.2 0.8-1.1 0.6-0.9 0.9-1.2 0.6-0.9 0.5-0.8 0.4-0.7 0.4-0.7 1.5-1.8 1.5-1.8 0.6-0.9 1.2-1.5 1.3-1.6 0.9-1.2
Tensile strength
ISO 527
  MPa
28 28 28 29 30 25 25 26 27 21 26 60 85 100 65 28 32 24 20 30 18
Flexural strength
ISO178
  MPa
38 38 39 42 45 35 36 39 42 31 40 82 108 130 84 35 48 37 34 36 33
Flexural modulus
ISO178
  MPa
2100 2400 2700 3100 4100 1800 2100 3000 4300 2000 3100 3100 4200 6000 5500 1400 1900 2800 2800 1600 1600
Charpy notched impact strength
ISO179/1eA
23℃
kJ/m2
8 7 6 5 4 7 6 5 3 46 16 7 12 13 8 7 3 4 2 15 6
Rockwell hardness
ISO 2039
R scale - 87 87 87 88 88 85 85 86 86 60 83 100 110 111 110 87 97 85 86 60 78
Deflection temperature under load
ISO 75
0.45MPa

112 115 117 129 133 102 107 118 135 114 115 155 160 160 160 95 110 130 115 92 82
Flamability
UL94
  - - - - - - - - - - - - HB HB HB - V-2
0.75 mm
V-0
0.75 mm
V-0
0.75 mm
V-0
equivalent
2.0mm
- V-1
2.0mm
Volume resistivit
ASTM D257
  Ω・m - - - - - - - - - - - - - - - - - - - 1.E+00 -
Surface resistivity
ASTM D257
  Ω - - - - - - - - - - - - - - - - - - - 1.E+02 1.E+08
Density
ISO 1183
  g/cm3
0.97 1.00 1.05 1.13 1.23 1.00 1.05 1.13 1.23 1.03 1.13 0.97 1.04 1.13 1.19 0.93 1.07 1.39 1.08 1.02 1.28

NOTES
1. UL recognition File No. of Daicel Polymer is E47773.
2. Values with asterisk (*) are UL-recognized values.

*"CELPURGE MA2" is recommendable for purging of PP.
For purging of filled grades or carbonized contamination, "CELPURGE AW2 / high cleaning type" or "CELPURGE AG4 / super cleaning type" is especially recommendable.