[Materials data sheet]
Novalloy S / PC/ABS

Properties Test method Test condition Unit General purpose GF-reinforced

Flame retardant

Standard Heat resistant GF10% GF20% GF30% V-0
Standard
V-0
Heat resistant
5VA
Standard
5VA
GF10%
5VA
GF20%
5VA
GF30%
V-0
GF10%
V-0
GF20%
V-0
GF30%
S1100 S1500 S1210 S1220 S1230 S3100 S3500 S4100
(TypeV)
S4210
(TypeV)
S4220
(TypeV)
S4230
(TypeV)
S5210 S5220 S5230
Mold shrinkage
ASTM D955
  % 0.4-0.6 0.4-0.6 0.2-0.5 0.1-0.4 0.1-0.3 0.4-0.6 0.4-0.6 0.4-0.6 0.2-0.5 0.2-0.5 0.1-0.4 0.2-0.5 0.1-0.4 0.1-0.3
Tensile strength
ISO 527
  MPa 53 52 72 86 98 50 52 50 59 78 92 75 95 120
Flexural strength
ISO178
  MPa 85 87 110 125 140 79 82 79 103 124 145 130 155 180
Flexural modulus
ISO178
  MPa 2400 2300 4000 5600 7600 2200 2400 2200 4200 5700 7700 4500 6500 9000
Charpy notched
impact strength
ISO179/1eA
23℃
-30℃
kJ/m2 60
28
60
44
11
-
9
-

8
-

50
20
50
20
14
-
7
-
7
-
8
-
7
5
7
-
9
8
Izod notched
Impact strength
ASTM D256
23℃ /6.4mm
23℃ /3.2mm
J/m 600
-
600
-
110
-
80
-
70
-
140
-
200
-
140
-
-
70
-
70
-
80
60
-
60
-
80
-
Deflection temperature
under load
ISO 75
AASTM D648
1.80MPa
1.82MPa/6.4mm

100
110
110
120
112
122
117
128
119
129
99
109
106
115
99
103
106
116
112
121
116
123
118
131
124
134
130
137
Coefficient of
thermal expansion
ISO 11359
MD
TD
×10-5/℃ 8
-
8
-
6
8
4
8
3
7
8
-
8
-
8
-
6
8
4
8
3
8
6
8
4
8
3
8
Flamability *
UL94
  - HB HB HB HB HB V-0/1.6mm V-0/1.5mm V-1/0.80mm
V-0/1.0mm
5VA/2.0mm
V-0/1.5mm
5VA/2.0mm
V-0/1.5mm
5VA/2.0mm
V-0/1.5mm
5VA/2.0mm
V-0/1.6mm V-0/1.6mm V-0/1.6mm
Dielectric strength
ASTM D149
1.5mm MV/m 36 37 36 35 35 35 28 28 26 26 26 27 27 29
Arc resistance *
ASTM D495
3.0mm sec
(PLC)
108
(6)
121
(6)
106
(6)
106
(6)
117
(6)
85
(6)
94
(6)
101
(6)
70
(6)
69
(6)
69
(6)
69
(6)
69
(6)
72
(6)
Hot wire ignition *
UL746A
1.5mm sec
(PLC)
16
(3)
12
(4)
54
(2)
54
(2)
98
(1)
45
(2)
19
(3)
26
(3)
150
(0)
150
(0)
150
(0)
42
(2)
42
(2)
150
(0)
High ampere arc ignition *
UL746A
1.5mm
(PLC)
200
(0)
200
(0)
29
(3)
15
(3)
15
(3)
150
(0)
73
(1)
36
(2)
150
(0)
149
(0)
149
(0)
150
(0)
150
(0)
150
(0)
High voltage tracking rate *
UL746A
3.0mm mm/min
(PLC)
35
(2)
56
(2)
94
(3)
94
(3)
64
(2)
127
(3)
220
(4)
230
(4)
267
(4)
300
(4)
300
(4)
281
(4)
281
(4)
141
(3)
Comparative tracking Index *
IEC 112
3.0mm V
(PLC)
275
(2)
275
(2)
175
(3)
175
(3)
175
(3)
400
(1)
250
(2)
600
(0)
100
(4)
100
(4)
100
(4)
190
(3)
190
(3)
190
(3)
Water absorption
ISO 62
  % 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3
Density
ISO 1183
  g/cm3
1.12 1.14 1.20 1.27 1.36 1.23 1.25 1.23 1.27 1.33 1.43 1.28 1.35 1.43

NOTES
1. UL recognition File No. of Daicel Polymer is E47773.
2. Values with asterisk (*) are UL-recognized values.

*"CELPURGE MA2" is recommendable for purging of Novalloy.
For purging of filled grades or carbonized contamination, "CELPURGE AW2 / high cleaning type" or "CELPURGE AG4 / super cleaning type" is especially recommendable.